Application and image quality evaluation of new domestic 320-slice CT in coronary artery imaging |
Received:May 10, 2021 Revised:July 08, 2021 Click here to download the full text |
Citation of this paper:YIN Le-kang,YAN Cheng,LU Yi-han,GUO Wei-feng,XU Shi-jie,LI Chen-wei,ZENG Meng-su.Application and image quality evaluation of new domestic 320-slice CT in coronary artery imaging[J].Chinese Journal of Clinical Medicine,2021,28(6):1035-1039 |
Hits: 1245 |
Download times: 474 |
Author Name | Affiliation | E-mail | YIN Le-kang | Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai 200032, China | | YAN Cheng | Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai 200032, China | | LU Yi-han | Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai 200032, China | | GUO Wei-feng | Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai 200032, China | | XU Shi-jie | Shanghai United Imaging Healthcare Co., Ltd, Shanghai 201807, China | | LI Chen-wei | Shanghai United Imaging Healthcare Co., Ltd, Shanghai 201807, China | | ZENG Meng-su | Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai 200032, China | zengmengsu_sh@163.com |
|
Abstract:Objective: The first 320-slice spiral CT independently developed in China had been approved for clinical application. In this study, this new CT equipment was used for coronary CT angiography (CCTA), and the imaging quality and radiation dose were preliminarily evaluated under different heart rate and cardiac rhythm conditions.Methods: From May 11, 2020 to June 19, 2020, a total of 160 patients underwent CCTA using this type of CT. The patients with sinus rhythm were divided into low heart rate group, medium heart rate group, and high heart rate group, and patients with arrhythmias were classified into arrhythmia group. The image quality of CCTA was graded at 4 levels, and the excellent rate and good rate of the images were calculated according to the score. The image quality distribution and effective doses of the proximal, middle, and distal segments of the coronary arteries under different rhythm and rates were analyzed. Results: 129 patients with normal heart rate (low heart rate group:40 cases; medium heart rate group:57 cases; high heart rate group:32 patients) and 17 patients with arrhythmia were included in this study. Totally, 1 929 coronary artery segments were evaluated, and the diagnostic rate was 99.79%. The overall excellent rate of coronary segments was 47.0%, and the good rate was 88.9%. The overall excellent and good rates of coronary artery images in the four groups were 88.4%, 89.4%, 88.4%, and 89.7%, respectively, with no statistically significant difference among different groups. The excellent rates were 48.2%, 50.1%, 45.8%, and 36.3% (P=0.004), respectively, and the excellent rates in the arrhythmia group were significantly lower than those in the low heart rate group and the moderate heart rate group (P=0.003 and 0.001, respectively). With the coronary artery branches from proximal to distal, the excellent rate and good rate of image quality decrease significantly. The effective dose of arrhythmia group was significantly higher than those of the other three groups (P<0.001).Conclusions: The new 320-slice spiral CT can obtain images that meet clinical diagnostic requirements under different heart rate and cardiac rhythm conditions, and the heart rate and cardiac rhythm factors have no effect on the overall quality of coronary images. |
keywords:coronary angiography computed tomography image quality arrhythmia |
HTML View Full Text View/Add Comment Download reader |
|
|
|