Clinical value of conventional ultrasound combined with virtual touch tissue imaging quantification (VTIQ) for breast lesions
Received:October 14, 2019  Revised:December 30, 2019  Click here to download the full text
Citation of this paper:WU Ai-qin,LIN Le-wu,LU Qing,YUAN Hai-xia,WANG Wen-ping.Clinical value of conventional ultrasound combined with virtual touch tissue imaging quantification (VTIQ) for breast lesions[J].Chinese Journal of Clinical Medicine,2020,27(4):666-669
Hits: 1651
Download times: 664
Author NameAffiliationE-mail
WU Ai-qin Department of Ultrasound, Xiamen Branch, Zhongshan Hospital, Fudan University, Xiamen 361015, Fujian, China  
LIN Le-wu Department of Ultrasound, Xiamen Branch, Zhongshan Hospital, Fudan University, Xiamen 361015, Fujian, China  
LU Qing Department of Ultrasound, Xiamen Branch, Zhongshan Hospital, Fudan University, Xiamen 361015, Fujian, China
Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai 200032, China 
 
YUAN Hai-xia Department of Ultrasound, Xiamen Branch, Zhongshan Hospital, Fudan University, Xiamen 361015, Fujian, China
Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai 200032, China 
haixiayuan75@163.com 
WANG Wen-ping Department of Ultrasound, Xiamen Branch, Zhongshan Hospital, Fudan University, Xiamen 361015, Fujian, China
Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai 200032, China 
puguang61@126.com 
Abstract:Objective: To explore the value of conventional ultrasound combined with virtual touch tissue imaging quantification (VTIQ) in differential diagnosis of benign and malignant breast lesions. Methods: Sixty-two breast lesions from Xiamen Branch, Zhongshan Hospital, Fudan University in April 2019 to September 2019 were examined by conventional ultrasound and VTIQ technique. The echo, morphology, punctate calcification and perforator blood flow were observed by conventional ultrasound. The SWVmax and the SWVmean of transverse shear wave velocity (SWV) were measured by VTIQ technique. The cut-off values of SWVmax and SWVmean were calculated by ROC curve based on pathological results. Diagnostic efficacy of conventional ultrasound combined with VITQ was compared with conventional ultrasound for breast lesions diagnosis. Results: Among 62 cases, 41 cases were benign tumors and 21 cases were malignant tumors. The cut-off points of SWVmax and SWVmean of VTIQ were 5.4 m/s and 4.2 m/s, respectively. The sensitivity and specificity of SWVmax and SWVmean were 72.0%, 92.1% and 86.0%, 79.0%. The sensitivity, specificity, accuracy, positive and negative predictive values of conventional ultrasound and conventional ultrasound combined with VTIQ were 68%,74%,42%,72%,83% vs 77%, 97%, 74%, 86%, 92% with significant difference(P<0.05). Conclusions: Conventional ultrasound combined with VTIQ is helpful to improve the diagnostic ability of conventional ultrasound for breast lesions, which is worthy of further promotion.
keywords:breast lesions  conventional ultrasound  virtual touch tissue imaging quantification  shrar ware velocity