Comparative study on increasing adenoma detection rate by adding indigo rouge in enteroscopy with water exchange method |
Received:July 27, 2019 Revised:November 26, 2019 Click here to download the full text |
Citation of this paper:HU Xue-jun,XU Wei,YAO Ping,SHEN Ming,ZHONG Xiao-feng,QIU Quan-xing,TANG Yu,HUA Hai-bing.Comparative study on increasing adenoma detection rate by adding indigo rouge in enteroscopy with water exchange method[J].Chinese Journal of Clinical Medicine,2019,26(6):923-926 |
Hits: 1514 |
Download times: 621 |
Author Name | Affiliation | E-mail | HU Xue-jun | Department of Gastroenterology, Jiangyin Hospital of Traditional Chinese Medicine, Jiangsu 214400, Jiangsu, China | | XU Wei | Department of Gastroenterology, Jiangyin Hospital of Traditional Chinese Medicine, Jiangsu 214400, Jiangsu, China | 879343048@qq.com | YAO Ping | Department of Gastroenterology, Jiangyin Hospital of Traditional Chinese Medicine, Jiangsu 214400, Jiangsu, China | | SHEN Ming | Department of Gastroenterology, Jiangyin Hospital of Traditional Chinese Medicine, Jiangsu 214400, Jiangsu, China | | ZHONG Xiao-feng | Department of Gastroenterology, Jiangyin Hospital of Traditional Chinese Medicine, Jiangsu 214400, Jiangsu, China | | QIU Quan-xing | Department of Gastroenterology, Jiangyin Hospital of Traditional Chinese Medicine, Jiangsu 214400, Jiangsu, China | | TANG Yu | Department of Gastroenterology, Jiangyin Hospital of Traditional Chinese Medicine, Jiangsu 214400, Jiangsu, China | | HUA Hai-bing | Department of Gastroenterology, Jiangyin Hospital of Traditional Chinese Medicine, Jiangsu 214400, Jiangsu, China | |
|
Abstract:Objective: To evaluate the efficacy of increasing adenoma detection rate (ADR) by adding indigo rouge in enteroscopy with water exchange method. Methods: Patients were enrolled prospectively. Colonoscopy was performed with routine water exchange (control group) or with 0.008% indigo carmine added water exchange method (study group). The primary outcome of this study is ADR. Results: Totally, 202 patients were included (101 cases in each group). There were no significant differences in gender distribution, mean age, smoking history, family history of colon cancer, and colonoscopy indication. Cecal intubation success rate was 100% in both groups. ADR was 31.7% for control group and 45.4% for study group, with significant difference (P<0.05). Conclusions: Adding 0.008% indigo rouge in enteroscopy with water exchange method enhances ADR significantly. |
keywords:adenoma detection rate colonoscopy water exchange method chromoendoscopy |
HTML View Full Text View/Add Comment Download reader |
|
|
|