Quick Search:       Advanced Search
Application and effect analysis of a self-made device to suspend the uterus in female laparoscopic radical rectectomy
Received:May 01, 2019  Revised:October 21, 2019  Click here to download the full text
Citation of this paper:ZHENG Wei-feng,XU Jian-min,CHEN Zhan,TU Yong-jiu.Application and effect analysis of a self-made device to suspend the uterus in female laparoscopic radical rectectomy[J].Chinese Journal of Clinical Medicine,2019,26(6):889-892
Hits: 1370
Download times: 610
Author NameAffiliationE-mail
ZHENG Wei-feng Department of General Surgery, The 73 rd Group Army Hospital of The People's Liberation Army(Success Hospital Affiliated to Xiamen University), Xiamen 361003, Fujian, China  
XU Jian-min Department of General Surgery, Zhongshan Hospital, Fudan University, Shanghai 200032, China  
CHEN Zhan Department of General Surgery, The 73 rd Group Army Hospital of The People's Liberation Army(Success Hospital Affiliated to Xiamen University), Xiamen 361003, Fujian, China  
TU Yong-jiu Department of General Surgery, The 73 rd Group Army Hospital of The People's Liberation Army(Success Hospital Affiliated to Xiamen University), Xiamen 361003, Fujian, China 707581937@qq.com 
Abstract:Objective: To introduce a self-made device to suspend the uterus in female laparoscopic radical rectectomy, and analyze its clinical application effect. Methods: Clinical data of 60 female patients underwent laparoscopic radical rectectomy from January 2016 to April 2019 in the Department of General Surgery, Success Hospital Affiliated To Xiamen University were analyzed retrospectively, and divided into observation and control groups. In the observation group (28), the self-made suspension uterine device was used in laparoscopic radical rectectomy in order to solve the difficulty of exposing pelvic surgical field covered by the prolapse of the uterus. The intraoperative and postoperative outcomes of the two groups were compared to evaluate the effect of the device. Results: The operative time and postoperative anal discharge time of the observation group were significantly shorter than that of the control group(P<0.05). There were no statistically significant differences in intraoperative blood loss, number of lymph node dissection, and incidence of postoperative complications. Conclusions: The self-made device to suspend the uterine in female laparoscopic radical rectectomy is easy to operate, with high security, and is cheap, meanwhile, it is beneficial to pelvic operation field exposure, reduces the risk and difficulty of operation, shortens operation time and postoperative anal exhaust time, and promotes postoperative recovery.
keywords:uterine suspending  laparoscopy  radical rectectomy
HTML  View Full Text  View/Add Comment  Download reader