Quick Search:       Advanced Search
Comparison of two aortic proximal anastomotic strategies during off-pump coronary artery bypass grafting
Received:July 20, 2021  Revised:September 29, 2021  Click here to download the full text
Citation of this paper:CHEN Zhen-hang,SHEN Jin-qiang,JIA Hao,SHAO Meng-ping,JI Qiang,LIU Chen,PAN Sun,LAI Hao,SUN Yong-xin,WEI Lai,DING Wen-jun,WANG Chun-sheng.Comparison of two aortic proximal anastomotic strategies during off-pump coronary artery bypass grafting[J].Chinese Journal of Clinical Medicine,2021,28(5):823-827
Hits: 817
Download times: 279
Author NameAffiliationE-mail
CHEN Zhen-hang Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China  
SHEN Jin-qiang Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China  
JIA Hao Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China  
SHAO Meng-ping Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China  
JI Qiang Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China  
LIU Chen Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China  
PAN Sun Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China  
LAI Hao Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China  
SUN Yong-xin Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China  
WEI Lai Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China  
DING Wen-jun Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China  
WANG Chun-sheng Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China wang.chunsheng@zs-hospital.sh.cn 
Abstract:Objective: To explore the clinical efficacy of two different aortic proximal anastomotic strategies:Heartstring device (HS) and partial clamping (PC) during off-pump coronary artery bypass grafting (OPCAB). Methods: Clinical data of 258 patients who underwent OPCAB procedure at the Department of Cardiovascular Surgery, Zhongshan Hospital, Fudan University from May 2018 to May 2021 were retrospectively analyzed, including 220 males and 38 females, with a mean age of 68.6±8.2 years. Patients were grouped according to different intraoperative aortic manipulation strategies:Heartstring clampless facilitating device group (HS, n=86) and partial clamp group (PC, n=172). Results: There were two cases of postoperative death (0.78%, one case in each group), and there were 7 cases of postoperative stroke 7 (2.13%; 1 in the HS group and 6 in the PC group, P=0.430). Conclusions: The Heartstring proximal anastomosis device can reduce aortic operation, and good short-term effects can be obtained for high-risk patients.
keywords:aortic proximal anastomotic device  off-pump coronary artery bypass grafting  coronary atherosclerotic cardiopathy